Laminar Malaysia Sdn Bhd
202301023304 (1517227-M)
WE'RE ON MAP
sales@laminar.my
Increase accuracy, frequency, and measurement quality using MID certified devices | Simplify device maintenance by using a mobile application with an intuitive interface and a large, graphic display. | Detect gas meter faults and deviations in natural gas consumption in real-time, enabling swift service response. | Remotely manage, configure, and analyse gas transmission processes using your dedicated data acquisition system. |
MacBAT 5 Gas Volume corrector Features
Electronic Gas Volume and Energy Corrector With 4G LTE Cat.1 Modem
Our MacBAT 5 corrector provide PTZ, PT, or T type corrections. The electronic device is powered by an internal battery with the option of external power connection. MacBAT 5 converts gas volume measured by a rotary, turbine, or ultrasonic gas flow meter to base conditions.
The gas compressibility factor is calculated using algorithms: SGERG-88, SGERG-mod-H2, AGA92-DC, AGA8-G1, AGA8-G2, AGA NX-19-mod, or a constant value of the compressibility factor K1.
The MacBAT 5 EVC is an intrinsically safe device that can be installed in Zone 0 explosive hazard areas.
About MacBAT 5 Electronic Volume Corrector
Direct data transmission to the system Reading data through the built-in 4G/2G modem with battery power supply. | Plz take the photos from this page: |
Remote data reading Connection via the communication interface INT-S3 and the built-in 4G/2G modem. | ![]() |
Local reading and configuration | ![]() |
Connecting MacBAT 5 with a rotary gas meter Connecting MacBAT 5 with a turbine gas meter using an external pressure sensor. Connection via 2 x LF ensures precise synchronization between the gas meter and the corrector, taking into account volume reversals on the gas meter. | ![]() |
Pressure measurement using MacBAT 5 operating with a turbine gas meter System recommended for operating a high-pressure gas meter. | ![]() |
Dimensions / weight: | version 1: 207 x 194 x 77 mm / 1.3 kg |
Relative humidity: | max. 95% at temp. 70°C |
Ambient temperature range: | min. -25°C, max. 70°C |
Enclosure protection rating: | IP66 for outdoor installations |
Display: | 4” graphical display |
Internal power supply: | one standard lithium battery size D 3.6V / 17 Ah, 5-year operating time |
Transmission protocols: | MODBUS RTU, MODBUS TCP (with integrated modem version), MODBUS RTU in MASTER mode, GAZMODEM 1, 2, 3 (other protocols available upon request) |
The gas volume corrector (EVC) measures accurately and convert the volume of gas to base conditions and, in some cases, to calculate the energy content of the gas. Its work is crucial to ensure gas volume measurements are standardized, which is important for billing, regulatory compliance, and technical evaluations.
The gas volume corrector operates by counting the volume at measurement conditions using pulses from either a low or high frequency sensor or directly from the gas meter counter with an encoder. It measures the gas’s pressure and temperature, converting the volume to base conditions and calculating the energy value based on preset gas parameters (EN 12405-1 and EN 12405-2).
In a gas EVC, the relationship between gas volume and pressure is adjusted to correct the gas volume to standard conditions using the principles of gas laws. As pressure increases (with temperature constant), the volume decreases, and as pressure decreases, the volume increases, with the gas EVC making the necessary corrections for accurate measurement and billing.
While room temperature and pressure are close to standard conditions, the gas EVC uses predefined standard reference conditions, such as 0°C or 15°C for temperature and 1 atmosphere for pressure, to correct the gas volume.
We’re passionate about what we do. Laminar Malaysia Sdn Bhd was founded in 2023 and aim to become an established supplier in Malaysia & the region, building a reputation for innovation and outstanding customer service.
Laminar Malaysia Sdn Bhd © 2025 All rights reserved
Designed and maintained by Ten-GB Pte Ltd